Compaq TaskSmart W2200 System Upgrade 1.03

Installation Instructions:

It is always a good practice to backup your system before performing any
system upgrade.  Backup your W2200 system before proceeding.

There are 4 methods for downloading and installation.  Please choose
the method which best matches your environment:

A - DIRECT METHOD (Single W2200's / direct access to public ftp site)
If you have access to Compaq's public ftp server from the W2200 system
and are only updating a single W2200 system, it is possible to download
and install this update in one step by using the Web Server Configuration
Application's System Upgrade Utility. After backing up your system proceed
to the DIRECT METHOD section. 

B - STAGING METHOD (Multiple or Single W2200 / No direct access to public
ftp site).  If you are updating multiple W2200 systems and/or you do not
have direct access to Compaq's public ftp site you will want to download
this rpm to a staging directory not necessarily located on the system(s)
you intend to update.  It is always a good practice to backup your system
before performing any system upgrade.  After backing up your system proceed
to the STAGING METHOD section.

C - CD METHOD (* For experienced Linux / Unix users only. RPM update file
has been burned to a CD-R / W2200 without access to the public ftp site or
private ftp / html server ). If you desire to burn the RPM update file to 
a cd and install from the cd drive of the unit to be upgraded follow the 
CD METHOD.  It is always a good practice to backup your system before 
performing any system upgrade.  After backing up your system proceed to 
the CD METHOD section.

D - W2200 FILESYSTEM METHOD (* For experienced Linux / Unix users only. 
RPM update file has been placed on the W2200 to be updated) If you desire 
to upgrade your W2200 system after downloading the .rpm file to the actual 
system to be updated follow the W2200 FILESYSTEM METHOD.  It is always a 
good practice to backup your system before performing any system upgrade.  
After backing up your system proceed to the W2200 FILESYSTEM METHOD 
section.

------------------


A - DIRECT METHOD ==================================================

1) Login to the Web Server Configuration Application as system
administrator.

2) Select "Management" from the left-hand navigation pane.  Select "System
Upgrade Utility" from the resulting drop down menu.

3) Use "anonymous" for the User Name field.  Leave the Password field 
empty.  Use the following URL for the "Location of the Upgrade" field:
"ftp://ftp.compaq.com/pub/products/servers/supportsoftware/linux
/RedHat/CompaqW2200-1.03-10.i386.rpm".  Select the "Download the Upgrade"
button.  The upgrade file is large and could take a considerable amount
of time depending upon your connection and current Internet conditions.

4) You will see the message "Downloading file... One moment please" .
Please read the important upgrade information and license agreement
which appears when the download is complete.  

6) Select the "Apply Upgrade" button after agreeing to the license
agreement to start the upgrade process.  After selecting the 'Apply
Upgrade' button, please WAIT FOR 10 MINUTES before resuming ANY activity
on the system. DO NOT USE THE WEB INTERFACE FOR 10 MINUTES.  Depending
on your current software version your system may be automatically
restarted.

7) After waiting for 10 minutes your upgrade should be complete and your
system ready for normal use.

RAPIDLAUNCH NOTE:
UID light functionality is unaffected when using RapidLaunch v2.3 or 
higher. The latest version of RapidLaunch, v2.3.91 or newer 
(Part No. 135199-403), may be installed for correct UID function -or- 
if using an older version of RapidLaunch the "SNMP Read" field must 
be changed to cpqPublic before the UID light will function properly.  
If using a version prior to 2.3 simply click the "Authentication" 
field for the selected device and change the "SNMP Read" field to 
cpqPublic.



B - STAGING METHOD ================================================

1) Download the upgrade package to a location which is accessible from
each of the W2200's you wish to upgrade.  This may be to a file share on
an ftp server or http server (web server).  The downloaded file is a linux
based rpm package with a filename based on the W2200 software version
number.

2) Login to the Web Server Configuration Application as system
administrator.

3) Select "Management" from the left-hand navigation pane.  Select "System
Upgrade Utility" from the resulting drop down menu.

4) Fill in the "User Name" and "Password" fields with the appropriate
information needed to access the system on which you have located the
CompaqW2200-1.03-10.i386.rpm upgrade file.  Fill in the "Location of the
Upgrade" field with the complete URL location for the
CompaqW2200-1.03-7.i386 upgrade file
( ex. ftp://ispserver2.bigisp.com/temp/CompaqW2200-1.03-10.i386.rpm ).
Select the "Download the Upgrade" button.  

5) You will see the message "Downloading file... One moment please" .
Please read the important upgrade information and license agreement
which appears when the download is complete. 

6) Select the "Apply Upgrade" button after agreeing to the license
agreement to start the upgrade process.  After selecting the 'Apply
Upgrade' button, please WAIT FOR 10 MINUTES before resuming ANY activity
on the system. DO NOT USE THE WEB INTERFACE FOR 10 MINUTES.  Depending
on your current software version your system may be automatically
restarted.

7) After waiting for 10 minutes your upgrade should be complete and your
system ready for normal use.

RAPIDLAUNCH NOTE:
UID light functionality is unaffected when using RapidLaunch v2.3 or 
higher. The latest version of RapidLaunch, v2.3.91 or newer 
(Part No. 135199-403), may be installed for correct UID function -or- 
if using an older version of RapidLaunch the "SNMP Read" field must 
be changed to cpqPublic before the UID light will function properly.  
If using a version prior to 2.3 simply click the "Authentication" 
field for the selected device and change the "SNMP Read" field to 
cpqPublic.



C - CD METHOD ======================================================
	* For experienced Linux / Unix users only

1) Burn the CompaqW2200-1.03-10.i386.rpm onto a CD-R.

2) Insert the CD into the CD drive of the W2200 server being upgraded.  

3) Create a user with ftp and telnet privileges through the Web Server 
Configuration Application.  

4) Using a client PC network accessible from the machine being upgraded, 
telnet into the W2200 system, change to root user (su - then password).
Mount the cdrom drive (mount /mnt/cdrom). Copy the rpm to the user's home 
directory (cp /mnt/cdrom/CompaqW2200-1.03-10.i386.rpm /home/USERNAME).  
Substitute the created user's name for USERNAME.

5) Login to the Web Server Configuration Application as system
administrator.

6) Select "Management" from the left-hand navigation pane.  Select "System
Upgrade Utility" from the resulting drop down menu.

7) Fill in the "User Name" and "Password" fields with the name and password
of the new user created in step 3.  Fill in the "Location of the Upgrade"
field with the local URL path to the file.  This will be 
ftp://127.0.0.1/home/USERNAME/CompaqW2200-1.03-10.i386.rpm .  Substitute
the created user's name for USERNAME. Select the "Download the Upgrade" 
button.

5) You will see the message "Downloading file... One moment please" .
Please read the important upgrade information and license agreement
which appears when the download is complete.  Proceed to step 6.

6) Select the "Apply Upgrade" button after agreeing to the license
agreement to start the upgrade process.  After selecting the 'Apply
Upgrade' button, please WAIT FOR 10 MINUTES before resuming ANY activity
on the system. DO NOT USE THE WEB INTERFACE FOR 10 MINUTES.  Depending
on your current software version your system may be automatically
restarted.

7) After waiting for 10 minutes your upgrade should be complete and your
system ready for normal use.

RAPIDLAUNCH NOTE:
UID light functionality is unaffected when using RapidLaunch v2.3 or 
higher. The latest version of RapidLaunch, v2.3.91 or newer 
(Part No. 135199-403), may be installed for correct UID function -or- 
if using an older version of RapidLaunch the "SNMP Read" field must 
be changed to cpqPublic before the UID light will function properly.  
If using a version prior to 2.3 simply click the "Authentication" 
field for the selected device and change the "SNMP Read" field to 
cpqPublic.



D - W2200 FILESYSTEM METHOD ===============================================
	* For experienced Linux / Unix users only

1) Create a user with ftp and telnet privileges through the Web Server 
Configuration Application.  

2) At the command line (telnet/console) of the W2200 on which the .rpm file 
resides, copy the rpm to the user's home directory 
(cp CompaqW2200-1.03-10.i386.rpm /home/USERNAME).  
Substitute the created user's name for USERNAME.

3) Login to the Web Server Configuration Application as system
administrator.

4) Select "Management" from the left-hand navigation pane.  Select "System
Upgrade Utility" from the resulting drop down menu.

5) Fill in the "User Name" and "Password" fields with the name and password
of the new user created in step 3.  Fill in the "Location of the Upgrade"
field with the local URL path to the file.  This will be 
ftp://127.0.0.1/home/USERNAME/CompaqW2200-1.03-10.i386.rpm .  Substitute
the created user's name for USERNAME. Select the "Download the Upgrade" 
button.

6) You will see the message "Downloading file... One moment please" .
Please read the important upgrade information and license agreement
which appears when the download is complete.  Proceed to step 6.

7) Select the "Apply Upgrade" button after agreeing to the license
agreement to start the upgrade process.  After selecting the 'Apply
Upgrade' button, please WAIT FOR 10 MINUTES before resuming ANY activity
on the system. DO NOT USE THE WEB INTERFACE FOR 10 MINUTES.  Depending
on your current software version your system may be automatically
restarted.

8) After waiting for 10 minutes your upgrade should be complete and your
system ready for normal use.

RAPIDLAUNCH NOTE:
UID light functionality is unaffected when using RapidLaunch v2.3 or 
higher. The latest version of RapidLaunch, v2.3.91 or newer 
(Part No. 135199-403), may be installed for correct UID function -or- 
if using an older version of RapidLaunch the "SNMP Read" field must 
be changed to cpqPublic before the UID light will function properly.  
If using a version prior to 2.3 simply click the "Authentication" 
field for the selected device and change the "SNMP Read" field to 
cpqPublic.


Copyright 2001, Compaq Computer Corporation.  All rights reserved.
Product names mentioned herein may be trademarks and/or registered 
trademarks of their respective companies.